Scene10cas

The Scene10cas is a Bluetooth-controllable, Casambi-enabled gateway device designed to interface with a standard two-channel 0–10VDC analog master controller. It converts analog voltage signals into Casambi Scene selection and Scene intensity control, enabling seamless integration of traditional 0–10V systems into a Casambi wireless lighting network.

Type: Casambi 0–10V Scene Gateway

0–10V Scene Selection:
Decodes two 0–10VDC channels, mapping the first channel into selectable voltage segments to trigger predefined Casambi Scenes.

Scene Intensity Control:
The second 0–10VDC channel provides 0–100% intensity adjustment for the selected Scene.

Voltage Trim & Hysteresis:
User-programmable top and bottom trim levels and hysteresis settings ensure stable operation even in installations with voltage fluctuation or signal noise.

Casambi App Configuration:
Easily configured through the Casambi app, allowing flexible mapping and integration with luminaires, groups, and complete lighting systems.

Mesh Network Functionality:
Operates within the Casambi mesh network, where each unit also acts as a repeater to extend wireless communication range.

Seamless 0–10V Integration:
Bridges traditional analog 0–10V control systems with modern Casambi wireless lighting networks.

Flexible Scene Management:
Enables remote selection and dynamic intensity control of multiple predefined Scenes.

Reliable Performance:
Programmable voltage trimming improves reliability in complex or noisy electrical environments.

Scalable Wireless Control:
Ideal for commercial and architectural projects transitioning from analog to smart lighting systems.

Input
Voltage range: 12–24 VDC, Class 2
No-load input current: 30 mA

0–10VDC Input (Channels A & B)
2-wire analog 0–10VDC, two channels
1 mA source current (input must sink for control)
Channel 1: Scene selection
Channel 2: Scene intensity (0–100%)
User programmable trim and hysteresis parameters

Radio Transceiver
Operating frequencies: 2.401–2.483 GHz
Maximum output power: typ. +0 dBm (±3 dBm)

Operating Conditions
Ambient temperature (ta): -25 to +45°C
Max. case temperature (tc): +75°C
Storage temperature: -25 to +75°C
Max. relative humidity: 0–80%, non-condensing

Connectors
Wire range, solid & stranded: 0.5–1.5 mm² (14–22 AWG)
Wire strip length: 6–7 mm
Tightening force: 0.4 Nm

Installation Notes
Do not install inside metal enclosures, as metal attenuates radio signals.
Use only with a Class 2 power supply (max. 100 VA output).
Comply with applicable electrical codes during installation.